BatteryTemperature
Text description
A temperature scale from about minus 10 to 110 degrees Fahrenheit, split into zones. Below 32 °F (0 °C), lithium iron phosphate batteries must not be charged unless they have a built-in heater or are kept warm, and lead-acid batteries lose a large share of their capacity. From 32 to 50 °F, it is still cold and capacity is lower. From about 50 to 80 °F (10 to 27 °C) is the range where most batteries do best; ratings are usually given at about 77 °F (25 °C). Above about 80 °F, heat shortens battery life for all types. A note says to check the maker's range for your battery.
CloudyWeekCharge
Text description
A chart of battery state of charge over seven days, with illustrative values. On days 1 and 2, which are sunny, the battery drops at night and refills to full each afternoon. Days 3 to 6 are cloudy: each day it charges only a little, and the charge steps down day by day from about 90 percent toward a dashed floor near 20 percent, the lowest charge planned for, set by the depth of discharge. Early on day 6 a generator tops it up to about 70 percent before it reaches the floor. On day 7 the sun returns and it refills. A bracket from the start of the cloudy spell to the generator start is labeled days of autonomy, how long the battery carries the loads with little sun.
ExampleLoadList
Text description
An example winter load list for a small off-grid cabin, with columns for watts, hours per day, days per week, and watt-hours per day, which is watts times hours times days per week, divided by 7. Fridge, which cycles on and off: 120 watts, about 8 hours of running a day, 960 watt-hours. Well pump: 1,000 watts, 1 hour, 1,000 watt-hours. Router and standby loads: 15 watts, 24 hours, 360 watt-hours. Microwave: 1,100 watts, a quarter hour, 275 watt-hours. LED lights: 50 watts, 5 hours, 250 watt-hours. Clothes washer: 500 watts, 1 hour, 3 days a week, about 214 watt-hours a day. Laptop and phones: 60 watts, 3 hours, 180 watt-hours. The daily total is about 3,240 watt-hours, or 3.2 kilowatt-hours. The fridge and the well pump together are more than half of it.
GeneratorPlacement
Text description
A plan view, seen from above and not to scale. A house has an attached garage, doors, windows and a vent. A portable generator sits outside, at least 20 feet (6 meters) from the house and garage, as the CPSC advises, with its exhaust pointing away from the building. A generator drawn inside the garage is crossed out, and so is one inside a shed: never run a generator indoors, in a garage, basement, crawlspace or shed, even with doors or windows open. Inside the house, CO alarms with batteries or battery backup are marked. Notes say carbon monoxide cannot be seen or smelled and can kill within minutes, and fans and open doors do not make it safe.
GridTiedDayNight
Text description
Three small block diagrams of a grid-tied solar system with no battery. On a sunny day, solar power runs the house first, and extra power flows out to the grid; many utilities credit this, often called net metering, under rules that vary. At night there is no solar, and the grid supplies the house. In a grid outage, the inverter shuts off, even in full sun, so no power flows anywhere; this protects utility line workers. A hybrid system with a battery is the option for backup.
HeatPumpCop
Text description
Two energy-flow sketches. Left, an electric resistance heater, such as a baseboard heater, with a coefficient of performance, or COP, of 1: one unit of electricity goes in and one unit of heat comes out. Right, a heat pump with a COP of 3: one unit of electricity goes in, two more units of heat are moved in from the outside air, and three units of heat come out into the house. A note says a heat pump's COP falls as the outdoor air gets colder, and cold-climate models are designed to keep a useful COP at lower temperatures.
LedVsIncandescent
Text description
Two area charts for bulbs that give about the same light, each on for 5 hours a night. The incandescent bulb draws 60 watts, so its rectangle is tall: 60 watts times 5 hours is 300 watt-hours. The LED bulb draws 9 watts, so its rectangle is short: 9 watts times 5 hours is 45 watt-hours. The LED uses about 85 percent less energy for the same light.
LossChain
Text description
A band of energy flows from left to right through six stages: panels, wires, charge controller, battery, inverter and plug. The band starts at 100 percent at the panels and gets a little narrower at each step, because each step loses some energy, mostly as heat, shown by small arrows rising off the band. At the plug, often only about 70 to 85 percent of what the panels made is left; the end of the band shows that range. A note says that saving 1 kilowatt-hour at the plug saves more than 1 kilowatt-hour at the panels.
MicroHydroHeadFlow
Text description
A side view of a hillside, not to scale. At the top, an intake takes water from a stream. A pipe carries it down the slope to a small turbine house at the bottom, and the water then returns to the stream. Head is the vertical drop from the intake to the turbine; net head is what is left after friction in the pipe, about 5 to 10 percent less for a first estimate. Flow is how much water passes, in gallons per minute. A box gives the DOE rule of thumb for small systems: net head in feet times flow in gallons per minute, divided by 10, is roughly the watts. Example: 100 feet times 20 gallons per minute, divided by 10, is about 200 watts, all day and night, about 4.8 kilowatt-hours a day.
MotorSurge
Text description
A sketch of a pump motor's power over a few seconds, not to scale. Before it starts, it draws nothing. As it starts, power jumps for a second or less to the surge, or starting watts, often 2 to 4 times the running watts, and sometimes more. Then it settles to the steady running watts. The shaded area under the line is the energy used; the surge spike adds only a sliver. Notes say the inverter must be able to handle the surge, and that a load list records surge watts for motor loads.
PanelTilt
Text description
A side view of a ground-mounted solar panel facing true south, to the right, at an example latitude of 40 degrees north. The solid panel is tilted at about the latitude, 40 degrees from flat, which gives good output across the year. A dashed steeper position, about latitude plus 10 to 15 degrees, favors the low winter sun and sheds snow better. A dashed flatter position favors summer. The high summer noon sun and the low winter noon sun are shown to the south, with sunlight reaching the panel.
PeakSunHours
Text description
A chart of sunlight strength through one day, from 7 in the morning to 5 in the evening, 10 hours of daylight. The real sunlight rises slowly in the morning, peaks around noon well below full strength, and falls in the afternoon; the area under this curve is shaded. A dashed box shows the same amount of energy as if it came at full test strength, 1,000 watts per square meter, for 4 hours around midday. The two areas are equal, so this day has 4 peak sun hours.
PowerAndEnergySizing
Text description
Two rows. Top row, power, in watts, meaning how fast electricity is used right now: a well pump, a microwave and a kettle running at the same time have watts that add up, and that total sets how big the inverter must be. Bottom row, energy, in watt-hours per day: the load list total, each load's watts times its hours, added up for the day, sets how big the battery and the solar array must be.
SeasonalSources
Text description
A chart of relative output by month, a common pattern rather than data for any one site. Solar output is low in winter, rises through spring and peaks in June and July. Wind is often strongest from late fall through early spring and weakest in summer. Stream flow for micro-hydro often peaks in spring, stays fair in winter, and drops in late summer and early fall; streams can also freeze. A shaded winter band shows where wind and hydro can fill in for solar.
SizingWorkflow
Text description
A flow diagram of the planning steps. Start with winter and summer load lists. They give daily kilowatt-hours; off grid, use the worst month. If the numbers feel too big, a loop arrow goes back to the load list: cut loads first. From daily kilowatt-hours, three results follow. Array size in kilowatts: daily kilowatt-hours divided by the sun hours for the worst month times the derate. Battery size in kilowatt-hours: daily kilowatt-hours times the days of autonomy, divided by the depth of discharge. Generator hours: to cover long cloudy spells and keep the rest smaller. All three go to a licensed installer, who turns this planning estimate into a real design.
SystemTypes
Text description
Three block diagrams side by side, showing power flows only, not wiring. Off-grid, with no utility connection: solar panels feed a charge controller, which charges a battery bank; an inverter-charger turns battery power into household power for the house loads, and a backup generator can charge the battery through the inverter-charger. In an outage there is no grid to lose; it keeps running from the battery. Grid-tied, usually with no battery: solar panels feed an inverter, which supplies the house loads; power flows both ways between the house and the utility grid. In an outage it shuts off, even in full sun, to protect line workers. Hybrid, a grid connection plus a battery: solar panels feed a hybrid inverter, which charges and draws from a battery bank, supplies the critical loads, and exchanges power with the utility grid. In an outage the critical loads keep running from the battery. A note says every system needs an electrical permit and inspection and a licensed installer, and grid-connected systems need utility approval.
TapAndBucket
Text description
Two taps fill two identical buckets to the same level. On the left, the tap is open a little, a thin stream, standing for low power used for a long time: a 10 watt LED bulb on for 5 hours, which is 10 watts times 5 hours, or 50 watt-hours. On the right, the tap is wide open, a thick stream, standing for high power used for a short time: a 1,000 watt kettle for 3 minutes, which is 1,000 watts times 0.05 hours, also 50 watt-hours. A dashed line joins the two water levels, marked same energy, 50 watt-hours. The width of the stream is power, in watts. The water in the bucket is energy, in watt-hours.
TransferSwitchConcept
Text description
A block diagram of the concept, not a wiring diagram. The utility grid and a generator both lead to a transfer switch or approved interlock, installed by a licensed electrician, which connects only one source at a time. From it, power goes to a critical-loads panel that feeds the circuits you most need, such as the fridge, the well pump and a few lights. A crossed-out path shows a generator plugged into a wall outlet with a homemade cord, called backfeeding: never do this. It can send power out to utility lines and kill line workers, and it can overload house wiring and start a fire.
UsableCapacity
Text description
A battery drawn as a long bar with a nameplate capacity of 10 kilowatt-hours. A scale below shows state of charge from 0 percent at the left to 100 percent at the right. The right half, from full down to 50 percent, is shaded as the part you use: a 50 percent depth of discharge, about 5 kilowatt-hours. The left half is kept in reserve and not used. A note says that deeper use gives more usable energy each cycle but wears the battery out sooner, so cycle life is shorter.
WindTowerHeight
Text description
A side view, not to scale. On the left, trees and a house break up the wind near the ground, making it slow and choppy, shown by wavy arrows. Higher up, the wind is smoother and faster, shown by straight arrows. On the right, a small wind turbine stands on a tall tower. A dashed line marks the top of the tallest obstacle nearby. The bottom of the turbine blades is at least 30 feet (9 meters) above that line, for anything within about 300 to 500 feet (90 to 150 meters) of the tower, following the DOE rule of thumb. A note says tower design and raising need a structural engineer and an experienced installer.
WinterShade
Text description
A side view, not to scale, with north to the left and south to the right. A ground-mounted solar array faces south. A tree stands some distance to its south. The high June noon sun casts a short shadow that ends well before the array. The low December noon sun casts a shadow several times longer, which reaches across the array. Shade on part of a panel can pull down the output of the whole string, so check the site at different times of day and year.
WinterSummerGap
Text description
A bar chart of daily energy from one example array, a 2 kilowatt array with an 80 percent derate, month by month, with illustrative sun hours. It makes about 3.2 to 3.5 kilowatt-hours a day in December and January and about 8.6 in June. A line shows daily use, a little higher in winter, about 4 to 4.3 kilowatt-hours, and about 3.3 in summer. In November, December and January the bars fall short of the line, shaded as the winter gap: size for this, or plan generator hours. From spring to fall the bars are well above the line, a summer surplus that is often unused off grid unless you add summer loads.