What you will make

In this project you make an energy plan with two parts:

  • A load list for winter and summer: every load, its watts and hours, and your daily kWh in each season.
  • A solar and battery sizing: the array size, battery size and generator hours that would cover those loads in your climate.

The result is a planning estimate, not a design. It gives you real numbers to compare quotes and ask good questions. It saves to My plan, on this device only.

The sizing path: a load list gives daily kWh for the worst month, which sets the array, the battery and the generator hours. Then a licensed installer turns it into a design.
Text description

A flow diagram of the planning steps. Start with winter and summer load lists. They give daily kilowatt-hours; off grid, use the worst month. If the numbers feel too big, a loop arrow goes back to the load list: cut loads first. From daily kilowatt-hours, three results follow. Array size in kilowatts: daily kilowatt-hours divided by the sun hours for the worst month times the derate. Battery size in kilowatt-hours: daily kilowatt-hours times the days of autonomy, divided by the depth of discharge. Generator hours: to cover long cloudy spells and keep the rest smaller. All three go to a licensed installer, who turns this planning estimate into a real design.

Gather your numbers

Have these ready:

  • Your appliance labels, or plug-in meter readings, for the main loads (lesson 22).
  • Twelve months of electric bills, if you have them (lesson 21).
  • Your location, for sun hours. The free PVWatts calculator gives monthly values.
  • Your climate zone, from your homestead brief.
  • Which loads you could move to other fuels, or swap for efficient ones (lesson 23).

Step 1: your load list

Enter each load with its watts and hours. Do a winter list first, then a summer list. Note surge watts for pumps and other motors.

Planning tool

Load calculator

List what you will run. Watts × hours × quantity × duty (the share of time it actually draws) gives watt-hours per day. Start from the examples and change them to match your own appliances.

Load list
ItemWattsHours/dayQtyDutySeasonWh/dayRemove
1,008
400
480
360
1,000
275
250
1,800
480

Winter: 5.6 kWh/day · Summer: 4.3 kWh/day

Everything on at once: 3,240 W. A realistic peak (the two biggest loads together plus some of the rest): about 2,442 W. That number helps size the inverter.

Biggest daily users: Furnace or stove blower fan (1,800 Wh), Fridge (efficient) (1,008 Wh), Well pump (1,000 Wh). Start your efficiency work there.

Motors such as pumps and fridges can draw two to several times their running watts for a moment when they start. Check the label or ask the installer.

Open My planNot saved yet.

A planning estimate, not a design. Take it to a qualified professional before you buy or build.

Before moving on, look at the top three loads. If one of them is heat, hot water or cooling, ask whether lesson 23 offers a cheaper swap. Changing it now shrinks everything in step 2.

Step 2: size solar and batteries

Now enter your daily kWh, your location’s sun hours, and how many days of autonomy you want. The tool estimates the array kW, the battery kWh and the generator hours for each month.

Planning tool

Solar and battery sizer

Size an off-grid array for the darkest month and a battery for a run of cloudy days. The results are ranges because real losses vary.

Not sure? See Lesson 3. Data is a teaching approximation for one city per zone.
About your latitude for year-round, steeper for winter.
Cloudy days the battery should carry with no sun. Often 2 to 5.

Loading climate data…

A planning estimate, not a design. Take it to a qualified professional before you buy or build.

Try it two ways: once with no generator, once with a generator allowed for a few hours a month. Compare the battery and array sizes.

Winter against summer

Look at the gap between your best and worst months.

  • Off grid, the array and battery are usually sized for the worst month, often December or January. In summer, the same array makes far more than you need. That extra is often wasted unless you add summer loads, such as pumping or cooling.
  • Grid-tied, you can size on the yearly total. The grid absorbs summer surplus and covers winter gaps, under your utility’s rules.

In a cold, cloudy zone, the winter array can be two or three times the summer one, or more. In a sunny southern zone, the gap is smaller.

The same array through the year. Off grid, the winter months set the size; in summer the array makes far more than the house uses.
Text description

A bar chart of daily energy from one example array, a 2 kilowatt array with an 80 percent derate, month by month, with illustrative sun hours. It makes about 3.2 to 3.5 kilowatt-hours a day in December and January and about 8.6 in June. A line shows daily use, a little higher in winter, about 4 to 4.3 kilowatt-hours, and about 3.3 in summer. In November, December and January the bars fall short of the line, shaded as the winter gap: size for this, or plan generator hours. From spring to fall the bars are well above the line, a summer surplus that is often unused off grid unless you add summer loads.

Reading your result

Check your result against a few questions:

  • Does the battery cover your days of autonomy at a safe depth of discharge for its type (lesson 25)?
  • Is the array in a spot with no winter shade?
  • Are the generator hours ones you could live with, in noise, fuel and time?
  • Does the inverter need to handle your biggest surge, such as the well pump starting?

If the numbers feel too big, go back to step 1. Efficiency changes usually cost less than more equipment.

What to take to an installer

An installer turns your plan into a real design. Bring:

  • Your winter and summer load lists, with surge watts for motors.
  • Your past bills or measured kWh, by month.
  • Your critical loads for outages.
  • Site photos: roof faces, open ground, trees and shade at different seasons.
  • Your sizing result, as a starting point, not a spec.

Check

Check your understanding

An off-grid plan uses 4 kWh a day all year. Sun hours are 5.5 in June and 1.8 in December. Which month should set the array size?

Summary and next steps

  • Your load list gives winter and summer kWh per day. Big loads matter most.
  • Off grid, size for the worst month. Grid-tied, size on the yearly total.
  • Close the winter gap with efficiency, tilt, a bigger array or generator hours. Each has a cost.
  • Your result is a planning estimate. Take it, with your load list and site photos, to a licensed installer.

Your energy plan joins your water budget in My plan. Next, the Heat track looks at the biggest load of all in cold climates.

Go deeper: why the tool shows ranges

Sun hours change from year to year, panels lose a little output each year, and batteries lose capacity as they age. Real loads also drift from any list. So the sizer shows ranges, not one number. Installers often add a margin on top for these effects. PVWatts can give monthly estimates for your exact site, roof angle and direction, which is a good next step before you talk to anyone.

Finish up

Mark this lesson complete to track your progress. It is saved only in this browser.

Sources

  1. PVWatts Calculator, National Laboratory of the Rockies (formerly the National Renewable Energy Laboratory, NREL)
  2. National Solar Radiation Database (NSRDB), National Laboratory of the Rockies (formerly the National Renewable Energy Laboratory, NREL)
  3. Off-Grid or Stand-Alone Renewable Energy Systems, US Department of Energy, Energy Saver (archived copy; the page was removed from energy.gov in mid-2026)
  4. Homeowner's Guide to Solar, US Department of Energy, Solar Energy Technologies Office
  5. Estimating Appliance and Home Electronic Energy Use, US Department of Energy, Energy Saver (archived copy; the page was removed from energy.gov in mid-2026)

Spotted an error? See Corrections for how to report it.